Myron L 729II Digital ORP Monitor Only
The advanced "isolated" circuitry of the 720 Series II ph/ORP Monitor/controllers guarantees accurate and reliable measurements, completely eliminating ground-loop and noise issues. The unique sensor preamp allows for longer distances between the sensor and the Monitor/controller without the loss of accuracy or reliability.
All Myron L/controllers feature a highly refined and precise Temperature Compensation Circuit. This feature perfectly matches the NERNST equation correcting the displayed reading to 25°C. The TC may be disabled to conform with USP requirements. Built-in electronic calibration allows for fast quality checks without standard solutions. For maximum system accuracy buffers are recommended.
A push to test button makes set point checks easy, while the internal alarm set discourages unauthorized adjustments. Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing reading. Bright green/red LED's indicate above or below set point readings.
All 720 Series II models feature an IP65/NEMA 4X water resistant and corrosion-proof rated enclosure. Compact in size at 6" x 4.8", they are suitable for panel, bench or surface mounting.
Features
Features
- Choice of 3-1/2" digit display or analog meter
- Advanced "Isolated" Circuitry
- Advanced "Isolated" Circuitry
- Automatic temperature compensation to 25°C
- Isolated 0-10 VDC Recorder Output standard
- IP65/NEMA 4x water resistant and corrosion proof enclosure
- Built-in electronic calibration
- Single set point/alarm
- Adjustable set point hysteresis
- Solid state 24 VDC output
- 10 amp relay operates on choice of increasing or decreasing reading
- Push-to-test setpoint discourages unauthorized adjustment
- Selectable 115/230 VAC
- Unique easily installed sensor
- Heavy Duty "F" model sensors may be installed in any direction including inverted
- Heavy Duty "F" model sensors may be installed in any direction including inverted
Applications
- Reverse Osmosis - Process Control
- Seawater Desalination - Waste Treatment
- Food Processing - Plating
- Power Plants - Laboratories
- Printing - Aquaculture
- Agriculture - Environmental Studies
- Medical - Bleach Manufacturing
- Cooling Towers - Reduction of Chromate Waste
- Range: +/- 2000 mV
- Display: Analog Models: 2.5"
Digital Models: .5" 3-1/2 Digit LCD
Optional: 3-1/2 Digit Baclit
- Linearity: +/- 0.05% (+/- 0.01 pH units/+/- 1mV of full scale)
- Resolution: Analog Meter: +/- 0.13 pH units/+/-40mV
Digital Display: +/-0.01 pH units/+/- 1mV
- Sensitivity: 0.05% of full scale (0.01 pH/+/- 1mV)
- Stability: 0.05% of full scale (0.01 pH/+/- 1mV)
- Repeatability: 0.05% of full scale (0.01 pH/+/- 1mV)
- Calibration Check: Built-in (7 and 0 pH/0 and -2000 mV)
- Recorder Output: Isolated 0-10 VDC @ 5 mA Max
- Sensor Input: 1 (3 input option is available)
- Power: 115/230 VAC, 50/60 Hz
- Maximum Power Consumption: @115V: 100 milliamps
- Dimensions: 6" H x 4.8" W x 3.8" D
- Ambient Temp Range: 32-140°F
- Weight: 2 lbs