Harmsco Pleated Polysulfone Membrane Cartridge, 0.65 Micron, 9-3/4 Inch Length, Case of 6, Water Service Grade
Harmsco High Purity Pleated Cartridges are manufactured for use in most applications where absolute rated filtration is needed
- SOLD AS A CASE OF 6
- Long service life- High flow rates
- Low pressure drops
- High permeability
Features
- 0.65 Micron
Features
- 0.65 Micron
- Hydrophilic polysulfone membrane
- Absolute rated pore sizes
- Thermal bonded polypropylene support structure
- Excellent flow vs. pressure drop
- USP Class VI - 121°C (250° F) for plastics
- 6 square feet of filtration media per 9-3/4" cartridge
- Extremely fast rinse up times
- FDA Listed Materials for potable water/liquid foods
Specifications
Specifications
Construction Materials
Membrane.................................Polysulfone (PS)
Support Media..........................Polypropylene
End Caps..................................Polypropylene
Center Core..............................Polypropylene
Outer Support Cage..................Polypropylene
O-Rings/Gaskets.......................Buna, Viton, EPDM, Silicon, Teflon Encapsulated Viton
Toxicity
All Polypropylene components meet the specifications for biological safety per USP Class VI: 250°F (121°C) for plastics
Dimensions
Length: 9-3/4"
Outside diameter: 2.7 inches (7.0 cm) nominal
Media Surface Area
6 square feet per 9-3/4" length
Maximum Recommended Operating Conditions
Temperature.................176°F (80°C)
Maximum Differential Pressures
Forward........................50 psi (3.4 bar) at 68°F (20°C)
Reverse.........................40 psi (2.7 bar) at 68°F (20°C)
FDA Listed Materials
Manufactured from materials which are listed for food contact applications in Title 21 of the US Code of Federal Regulations
Sanitization/Sterilization
Filtered hot water.................176°F (80°C) for 30 minutes
Steam Sterilization................250°F (121°C) for 30 minutes
Chemicals.............................Cartridges are chemically compatible with most chemicals and sanitizing points
Note: Stainless stell insert option needed for all cartridges being hot water sanitized or steam sterilized
- Food & Beverage - Fine Chemicals
- Cosmetics - Plating Chemicals
- Photographic Solutions - Wastewater
- Reagent and Electronic Grade Chemicals - Pharmaceuticals & Biologicals
- Bottle Water - Ophthalmics
- Prefiltration Prior to membrane filters
- DI and RO feedwater prefiltration
- Magnetic media chemicals
- Process Water