GreensandPlus is a purple-gray filter media used for removing soluble iron, manganese, hydrogen sulfide, arsenic and radium from well water supplies.

Like its sister product manganese greensand, the substrate media has a manganese dioxide coated surface that acts as a catalyst in the oxidation-reduction reaction of iron and manganese. The difference between GreensandPlus and Manganese Greensand is in the substrate that forms the core of the media and the method by which the manganese dioxide coating is attached to that substrate. GreensandPlus has a silica sand core and the coating is fused to it while Manganese Greensand has a glauconite core and the coating is ionically bound to it.

Along with the added benefits comes the fact that GreensandPlus is an exact replacement for manganese greensand. It can be used in CR and IR applications and requires no changes in backwash rate or times or chemical feeds.

The silica sand core of GreensandPlus allows it to better withstand operating conditions in waters that are low in silica, TDS and hardness. Thus, if you currently are using manganese greensand and are feeding sodium aluminate, you will likely be able to eliminate the aluminate feed by switching to GreensandPlus. Also GreensandPlus can withstand higher operating temperatures and higher differential pressures than can manganese greensand. The higher differential pressure may allow for a longer run length, but, if nothing else, allows for more operational margin of error.

GreensandPlus is a purple-gray filter media used for removing soluble iron, manganese, hydrogen sulfide, arsenic and radium from well water supplies.

Advantages:
- Iron removal over a wide pH range
- Effective removal of hydrogen sulfide in addition to iron and/or manganese
- No harmful effects from a chlorine feed
- Low attrition loss for long bed life

Physical Properties:
- Color.......................................Black nodular granules
- Density....................................85 lbs/cu. ft.
- Effective Size..........................0.30-0.35 mm
- Uniform Coefficient................1.6
- Mesh Size................................18 x 60
- Attrition Loss Per Year............2%

Capacity/Cu. Ft.:
- Iron Alone...............................550 gr. (10,000 gallons of water containing 1 ppm iron)
- Iron and Manganese................400 gr. (7,000 gallons of water containing 1/2 ppm iron and 1/2 ppm manganese/cu. ft.)
- Hydrogen Sulfide....................175 gr. (3,000 gallons of water containing 1 ppm hydrogen sulfide/cu. ft)

Conditions for Operation:
- Raw Water pH..........................6.2-8.5
- Bed Depth.................................30 in.
- Freeboard..................................35-50%
- Service Flow Rate.....................2-5 gpm/sq. ft.
- Backwash Flow Rate................12 gpm/sq. ft.
- Maximum Temperature.............No Limit
- Maximum Practical Limit of Iron (Fe++) or Manganese (Mn++) In Raw Water......15 ppm
- Maximum Practical Limit of Hydrogen Sulfide (H2S).........5 ppm